1000L specification drawing
Dimensions
- 1500mm (L) x 850mm (W) x 1000mm (H)
Mactrap 1000L passive trap
- Sink/pick up point should be above inlet pipe
- Max/Min inlet invert = 850mm
- Max/Min outlet/invert = 780mm
- Wallace seals to suit 100mm drainpipe
- Flexible couplings to suit earth movement requirements
- <65C continuous operating temperature
- All Mactrap passive traps must be vented. See Installation and Maintenance
- Top inlet/outlet positions can be installed - please contact us for more information